Q99. The access control management function of NETECO cannot modify the door name.

 
 

Q100. Which of the following functions belong to the FusionModule2000 controller (ECC800)? (Multiple choice)

 
 
 

Q101. What is the maximum number of cabinets in the FusionModule500 & FusionModule800 modules?

 
 
 
 

Q102. Before the battery is installed, the open circuit voltage of a single battery is required: 12V battery ≥ 12 60V or 2V TV ≥ 2 10V, when it is found to be unqualified, the battery needs to be supplemented.

 
 

Q103. The location of the data center needs to be evaluated () factors. (Multiple choice)

 
 
 
 

Q104. In FusionModule1000B series solutions, when 2N power supply and distribution system is selected, can meet TIER4 wind power requirements.

 
 

Q105. The rated voltage of the cell (CELL) in the VRLA battery is ().

 
 
 
 

Q106. The power supply structure adopted by the new line-level half-cabinet chilled water is:

 
 
 
 

Q107. Traditional UPS. The number of battery cells is not adjustable, the maintenance cost of the battery is high, and the damage of one battery may lead to the replacement of the entire battery pack. The number of battery cells of UPS5000-A is adjustable, then the adjustable range is?

 
 
 
 

Q108. APM, NR and other UPS products need to be derated at 30 degrees, and UPS5000-E does not need to be below 40 degrees.

 
 

Q109. In ECO mode, when the input is stable, the UPS works in () state.

 
 
 
 

Q110. When the polling function is turned on, the running machine and the standby machine can be exchanged, thereby improving the average lifespan.

 
 

Q111. Regarding the cabinet rPDU of FusionModule2000, which of the following statements is false?

 
 
 

Q112. When UPS2000-G-(6-20KVA) is in ECO mode, the battery indicator and bypass indicator are on at the same time.

 
 

Q113. FusionModule800 has the function of self-starting of civil air conditioners.

 
 